Aama 2603 pdf converter

Standardspecification for windows, doors, and unit skylights. The aama 502 voluntary specification for field testing of newly installed fenestration products is a fieldtesting guide developed by the american architectural manufacturers association aama. Aama official site american association of medical. The steps are grouped into two main categories, including four steps prior to testing and three steps during and after testing. Aama 260505 voluntary specification, performance requirements. Aama 2604 light commercial products extrusion coatings aama 2604 light commercial the american architectural manufacturers association aama analyzes products to provide architects with benchmarks for quality in selecting the right materials for new construction and renovation projects. American architectural manufacturers association aama performance requirements for pigmented organic coatings defined. The baked enamel coatings are harder than the pvdf fluoropolymer coatings and are used quite often for interior application where color retention is not required. Aama 502 was completed first, followed by aama 503. Aama specification 2603 2604 2605 2605 coating layers one coat one coat one coat primer topcoat warranty 5 years 10 years 20 years 20 years seacoast coverage no no no yes humidity aama spec 1,500 hours 3,000 hours 4,000 hours 4,000 hours salt spray aama spec 1,500 hours 3,000 hours 4,000 hours 4,000 hours south florida weathering aama spec. Regis, courtyard, westbury, screenrail, designer fencing and aluminum chr. Aama and its members moved forward to rectify these issues.

Excel to vcard software is an influential and 100% result oriented program to convert ms excel database to vcard file in easy way. Selecting a powder coat performance specification that is best for architectural railing aama 260302 to meet the aama 2603 specification, powder coatings are most often formulated with standard durable polyester binder. The product is installed under cover but could be subject to the outdoor environment. Nafs north american fenestration standardspecification. Includes information from the previous aama 620 document. Aama 603 and aama 605 as the standards for testing and performance of organic coatings on architectural aluminum extrusions and panels. Aama 2300 and aama 2301 were removed because they were never completed and published. Aama 50392 voluntary specification for field testing of metal storefronts, curtain walls and sloped glazing systems aama 501. Selecting a powder coat performance specification that is best for architectural railing aama 2603 02 to meet the aama 2603 specification, powder coatings are most often formulated with standard durable polyester binder. Powder coating solutions for every architectural specification.

Phosphate conversion coating is mandated for aama 260598, the. May 22, 20 we manufacture steel and aluminum outdoor products. Cma aama recertification by continuing education applications. Abrasion coefficient value 0 to 116 creepage from scribe is passing digger specialties coating processes are verified aama 260405 compliant. Voluntary test method for thermal transmittance and condensation resistance of windows, doors and glazed wall sections see other formats. The attributes of color and gloss are utilized to determine how well a coating will withstand harsh environmental conditions. Aama 241003 standard practice for installation of windows. Aama standards comparison organic coati ngs on aluminum. This test is utilized to provide quality assurance and diagnostic field water penetration check method for installed storefronts, curtain walls and sloped glazing systems. Trudurance architectural color card tci powder coatings. The 2603 and 2604 ranges can be delivered in either matte or fine.

We developed our high quality powder coatings to comply with aama 2603 specifications. Aama has developed standards that describe laboratory test meth ods and performance criteria for organic finishes on aluminum pro files. Its hard surface and resistance to cleaning solutions also makes it an excellent selection for the interior of windows and doors. End uses acrylic super hard aama 2603 coating for use on the. Our coating stood up to some of the toughest test specifications, including adhesion, abrasion resistance, chemical resistance. Aama 61112 references important industry standards which include aama 609 and 61009, cleaning and maintenance guide for architecturally finished aluminum, aama 80010, voluntary specifications and test methods for sealants and astm b795 2009, standard test method for measurement of coating mass per unit area on anodically coated. Curtain wall, extrusion, facade, storefront, windows and doors, oceanfront residences and businesses. This guide illustrates test procedures to ensure air and moisture penetration is minimized in new window installations. Starting with information gathering, the forensic investigator performs the following.

Aama american architectural manufacturers association aama 50290 voluntary specification for field testing of windows and sliding glass doors. Publication no home ppg architectural metal coatings. Sitc conducts aama quality assurance water spray testing and aama investigative water spray testing. Nafs north american fenestration standardspecification for. Aama publishes forensic water testing guideline page 2 of 3 information regarding each step. Fluoropolymer coatings generally meet one of the three. Do the aama powder coat specifications for extruded aluminumaama 2603, aama 2604 and aama 2605correlate to the application of steel materials. Am looking for an appropriate standard to apply to powder coating on aluminum extrusions. All aama documents may be ordered at our web site in the publications store. Specifications for powder coated aluminum aama 2603, 2604. The twocoat system consists of a color coat and a clear coat, and is sprayapplied to extruded aluminum.

End uses hard aama 2603 coating for use on the exterior 2603. Excerpt editions do not reflect updates that were issued after the initial publication of the standardspecification. Aama window standards specifications and ratings, testing. For aluminum profiles, these standards are aama 2603, 2604 and 2605, which set the criteria for basic, highperformance and supe riorperformance organic coatings respectively. Aama 2603, voluntary specification, performance requirements and test procedures for pigmented organic. Extrusion coating system meets aama 2605 specifications.

The american architectural manufacturer association known as aama is the leading trade association that representing the high standard of quality certification for manufacturers and suppliers. Several drafts were written by the field test task group with the intent to do a clean sweep of the documents. Through a unique combination of acrylic and fluoropolymer resins, flurocryl provides excellent hardness, flexibility and mar resistance in a solventborne baked enamel system, equaling or exceeding the hardness of other acrylic, polyester, or urethane. All of tcis ral products meet or exceed aama 2603 specifications, please refer to the index for colors that meet the 2604 specification tci ral products have been matched to original ral color master standards tci ral products are designed to be used in both indoor and outdoor applications tci ral products have a gloss range between 8095%. Aama and igma, two industry leaders, have unified to form an exponentially stronger alliance. Submit your application and documentation electronically via the apply to recertify by ce webpage. Aama 2604 light commercial ppg architectural metal coatings. Aama american architectural manufacturers association. Evolution of the requirements for anticorrosion protection of road. Through a unique combination of acrylic and fluoropolymer resins, flurocryl provides excellent hardness, flexibility and mar resistance in a solventborne baked enamel system, equaling or exceeding the hardness of other acrylic, polyester, or urethane coatings including powder coating alternatives.

Aama is comprised of a variety of companies, including window, door and skylight manufacturers, component and supply manufacturers, service and consulting companies. End uses acrylic super hard aama 2603 coating for use. Other new generation products include conversion coatings, which improve the adhesion. Aama standards identified as aama 2603, 2604, or 2605. No blistering or visual change for aama 2603, 2604, 2605. If so, are there any metrics for how similar powder coats will react differently on steel. Aama standards comparison organic coati ngs on aluminum extrusions and panels attribute aama 260302 basic pigmented coatings aama 260410 high performance coatings aama 260511 superior coatings minimum initial dry film thickness 20 microns 0. American architectural manufacturers association aama water spray testing is a service that sovell investigative testing and consulting sitc has been suppling our customers for ten years. In this version, an appendix was added describing differences in test procedures and performance requirements for aama 2603 for pigmented organic coatings, applied on a coil coating line, to aluminum architectural products. Trudurance architectural color card download pdf aama 2603 stock colors. Gsb standard and aama 2603 standard with a film thickness of minimum 60 microns all in accordance to manufacturers instruction. Ansi was removed from the document title ansiaama 1002.

Aama 2605, aama 2604 and aama 2603 coatings servicing architects, building professionals, designers, construction managers, engineers and most importantly the owner and end user of these prestigious projects. Significant advances have been made in technology which have created the need to revise these specifications. Appropriate for applications such as ceiling panels, supports and interior windows. Specifications for powder coated aluminum aama 2603, 2604, 2605 1996. Designed to help our members excel in a dynamic and fastmoving future, the fenestration and glazing industry alliance, or fgia, is focused on building better industry synergies from glass to framing. May, 2014 the resulting finish meets or exceeds aama 2605 specifications for 10year south florida exposure weathering conditions and resistance to salt spray, chalking and fading. When selecting a coating that will be required to stand up to harsh coastal or corrosive environments either the highestperforming organic paint coating, that meets the aama 260511 specification, or a class i anodize coating that meets aama 61112 should be selected. Essentially the same changes were made to both documents, however aama 503 is written. The resulting finish meets or exceeds aama 2605 specifications for 10year south florida exposure weathering conditions and resistance to salt spray, chalking and fading. Aama 260405 certification our sevenstep powdercoat system exceeds aama 260405 american architectural manufacturers association test specificationsone of the highest in the industry. American architectural materials association aama specifications and earth metal specifiers and building owners need to determine which performance criteria is required for their project aama 2603. In this version, an appendix was added describing differences in test procedures and performance requirements for aama 2605 for superior performing organic coatings, applied on a coil coating line, to aluminum architectural products.

By order of the executive director office of the federal register washington, d. Aama releases updated specification for anodized aluminum. See below for details on the extension given to all those with cma aama credentials originally set to expire on march 31, 2020, april 30, 2020, and may 31, 2020. Aama 2603 paint specification aama 2603 is typically an interior specification. Aama 2604 powder coated finish elite fence product, inc. Chrome containing conversion coating weights should be. The proper finish and attention of aluminum windows t aama. Any of a variety of compounds used to fill and seal joints or openings in wood, metal, masonry, and other materials, as contrasted to a sealer. Aama 2603 is typically an interior specification, such as ceiling panels, supports and interior windows. Formerly cawm 40095 standard practice for installation of.

1616 1304 1081 1526 389 411 682 1088 1362 894 453 64 1622 1583 1369 1234 749 158 1670 835 1286 1326 550 383 2 450 196 376 1301 122 70 1377 331 137 821 23